Service manual

7 – 13
7.3.6 PCB6 (WK-5460) and Q1A-Q2C “Primary IGBT” VX
1) Remove the Side Panel. [See section "6.1-1"]
2) Remove the four screws and two IGBT Spring Clips. Remove the cables from edge holder.
3) Disconnect the connector CN1 on the PCB6. Cut the lead of the Q1A-Q2C.
Remember to install new Silicone Rubber Sheets where silicone compound (Shinetsu Silicone G-747 or
equivalent) was spread when reinstalling the PCB6. Spread the silicone compound on IGBT.
1
1
2
3
CN1
1 1
2
SERVICE MANUAL
MAINTENANCE
TRANSTIG 200 Pi