Service manual
7 – 11
7.3.4 PCB4 (WK-5449) V
1) Remove the Side Panel. [See section "6.1-1"]
2) Remove the Protection Cover.
3) Remove the Knob Cap. Holding the Knob down, loosen the screw and remove the Knob.
4) Disconnect the two connectors CN1,3 on the PCB4. Remove the four screws. Pull out the operation
panel and bring it down.
3
1
2
2
2
3
1
3
1
1
2
2
2
2
CN1
CN3
SERVICE MANUAL
MAINTENANCE
TRANSTIG 200 Pi