Service manual

6 – 5
SERVICE MANUAL ADVANCED TROUBLESHOOTING TRANSTIG 200 Pi
6.2.6 E04 "Torch Cable Failure"
Cause
The combined length of the torch cable and the
work cable is too long.
Verification/Remedy
a) Verify the rated duty cycle of the torch/work
cable and the power supply.
Only use appropriate sized torch cables
(length and capacity). The recommended
total combined length of the torch and work
cable is 50 feet.
Torch and work cable should not be "coiled"
during welding operations.
Maintain the duty cycle of the power supply.
Refer to section 3.8 for the recommended
duty cycle.
b) Replace PCB6 (WK-5549)
Refer to section 12.3.6 for the replacement of
PCB6.
6.2.7 E93 "Memory chip (EEPROM)
error."
Cause
Memory chip (EEPROM) on control PCB can not
read/write weld parameters.
Verification/Remedy
a) Replace Control Board PCB4 (WK-5549).
• Refer to section 7.3.4 for the replacement of
PCB4.