Service manual

TRANSTIG 200 Pi SERVICE MANUAL
4-4
March 31, 2008
Parameter Description
DOWN SLOPE
This parameter operates in TIG modes only and is used to set the time for the weld
current to ramp down, after the torch trigger switch has been pressed, to
CRATER
CUR.
This control is used to eliminate the crater that can form at the completion of a
weld.
CRATER CUR.
This parameter operates in
SLOP
E
or
REPEA
T
(4T) TIG modes only and is used to
set the finish current for TIG. The CRATER Current remains on until the torch trigger
switch is released after it has been depressed.
POST-FLOW
This parameter operates in TIG modes only and is used to adjust the post gas flow
time once the arc has extinguished. This control is used to dramatically reduce
oxidation of the tungsten electrode.
The SAVE/LOAD buttons are used to save and retrieve a total number of 5 programs
into the 200 Pi memory. NOTE: SAVE/LOAD button must remain depressed for 3
seconds in order to save or load the settings.
Table 4-3 (continued): Parameter Descriptions
4.04 Weld Parameters for Transtig 200 Pi
Weld
Parameter
Parameter
Range
Factory
Setting
Incremental
Unit
STICK
HF
TIG
LIFT
TIG
PRE-FLOW
0.0 to 1.0 sec 0.1 sec 0.1 sec No Yes Yes
HOT START
0 to 70A 20A 1A Yes Yes No
INITIAL CUR.
1 to 200A 30A 1A No Yes Yes
UP SLOPE
0 to 15 sec 1 sec 0.1 sec No Yes Yes
PEAK CUR.
1 to 200A 120A 1A No Yes Yes
WELD CUR
1 to 200A 230V 80A 1A No Yes Yes
(TIG)
1 to 85A 115V 80A 1A No Yes Yes
WELD CUR
1 to 160A 230V 80A 1A Yes No No
(STICK)
1 to 85A 115V 80A 1A Yes No No
SPOT TIME
0.5 to 5.0 sec 2 sec 0.1 sec No Yes Yes
PULSE WIDTH
15 to 80% 50% 1% No Yes Yes
PULSE FREQ.
0.5 to 500Hz 100.0Hz See Table 4-5 No Yes Yes
DOWN SLOPE
0 to 25 sec 3 sec 0.1 sec No Yes Yes
CRATER CUR.
1 to 200A 30A 1A No Yes Yes
POST-FLOW
0.0 to 60 sec 10 sec 0.1 sec No Yes Yes
Weld Mode
Table 4-4: Weld Parameters for Transtig 200 Pi
PULSE FREQ. Range Incremental Unit
0.5 to 20Hz 0.1Hz
20 to 100Hz 1Hz
100 to 500Hz 5Hz
Table 4-5: PULSE FREQ. Range and Incremental Units