User guide

20835-01 Rev 04
Page 9-14
9.4.3 Flow/GVF Initial Setup
In order to conduct measurements, the ‘Basic Config’ setup must be
completed. If power goes off, this setup will remain in memory and
does not have to be re-entered.
Press any key except ‘EXIT’ on the keypad to enter the ‘Menu
Mode’.
When ‘Basic Configmenu is displayed on Line 1 of the display
press the ‘ENTER’ key to enter the options available under that
menu.
→Sensor Serial #’ will appear on Line 2 of the display. Press the
ENTER’ key and the current sensor band serial number entered in
the transmitter will be displayed on Line 4 of the display. The user
can then use the arrow keys ( and to scroll through the values
and and to change position) to enter the sensor serial
number. Once all digits are entered, press the ENTER’ key to
save to memory. ‘→Sensor Serial #’ will again be displayed on
Line 2.
Next, press the key to scroll to the ‘Pipe Size’ menu on Line 2.
Press the ENTER’ key to access the options available under that
menu. Note: it is necessary to select only one of the following
options.
The first choice on the Pipe Size’ menu is ‘ID / Wall’ shown on
Line 3 of the display. If this value is known it can be entered here.
Press the ENTER’ key and the current saved inner diameter and
wall thickness will be shown on Line 4 of the display. Use the
arrow keys ( and to scroll through the values and and to
change character) to enter the pipe inner diameter. Units can be
inches or millimeters. Once all digits are entered, press the
ENTER’ key to save the value to memory.
The second choice on the Pipe Size’ menu is ‘Size/Sched’ (pipe
Size / Schedule). If this value is known press the ENTER’ key.
Use the arrow keys to enter the values and then press the
ENTER’ key to save to memory.
The third choice on the Pipe Size’ menu is ‘OD / Wall’ displayed
on Line 3. Use the arrow keys ( and to scroll through the values
and and to change character) to enter the pipe inner
diameter. Units can be inches or millimeters. Once all digits are
entered, press the ENTER’ key to save the value to memory.
Following the entering of ‘Pipe Size’ press the ‘BACK’ key and
→Pipe Size’ will be displayed on Line 2. At this point the user can
either press the ENTER’ key to re-enter the ‘Pipe Size’ menu or
press the key to move to the next menu item.