Owner's manual

Table 5 Modbus Holding Registers (continued)
Address Size Type Value Description Values
1069 1 Char
420_OVERRANGE_
MODE_
02
Selects 4-20mA Channel 2 Overrange rail.
0 = Use
PRIMARY_4
20_OUT_OF_RANG
E setting when output is below/
above lowcut/highcut % (do not
rail), 1 = Rail 4-20mA output if
metric is below/above
lowcut/highcut % for channel 1
1070 1 Char
PULSE_OUTPUT_S
EL
Selects metric output on pulse.
0 = Flow Rate, 1 = SOS, 2 = GVF,
3 = Flo
w Rate %, 4 = Totalizer, 5
= TLF, 6 = Flow Quality, 7 = SOS
Quality
1071 1 Char PULSE_WIDTH Selects pulse width.
0 = 0.5, 1 = 1, 2 = 20, 3 = 33, 4 =
50, 5 = 100
1072 1 Char
ALARM_WARN_EX
PR_0
Boolean expression used for warning alarm. 0 = OFF, 1 = ON
1073 1 Char
ALARM_WARN_EX
PR_1
Boolean expression used for warning alarm.
2 = Blank, 3 = TMP, 4 = SPL, 5 =
VQ, 6 = SQ, 7 = LOG, 8 =
OVL, 9
= FAL, 10 = FLW, 11 = GVF
1074 1 Char
ALARM_WARN_EX
PR_2
Boolean expression used for warning alarm. 0 = Blank, 1 = OR, 2 = AND
1075 1 Char
ALARM_WARN_EX
PR_3
Boolean expression used for warning alarm.
2 = Blank, 3 = TMP, 4 = SPL, 5 =
VQ, 6 = SQ, 7 = LOG, 8 =
OVL, 9
= FAL, 10 = FLW, 11 = GVF
1076 1 Char
ALARM_WARN_EX
PR_4
Boolean expression used for warning alarm. 0 = Blank, 1 = OR, 2 = AND
1077 1 Char
ALARM_WARN_EX
PR_5
Boolean expression used for warning alarm.
2 = Blank, 3 = TMP, 4 = SPL, 5 =
VQ, 6 = SQ, 7 = LOG, 8 =
OVL, 9
= FAL, 10 = FLW, 11 = GVF
1078 1 Char
ALARM_CRIT_EXP
R_0
Boolean expression used for critical alarm. 0 = OFF, 1 = ON
1079 1 Char
ALARM_CRIT_EXP
R_1
Boolean expression used for critical alarm.
2 = Blank, 3 = TMP, 4 = SPL, 5 =
VQ, 6 = SQ, 7 = LOG, 8 =
OVL, 9
= FAL, 10 = FLW, 11 = GVF
20959-01 Rev 02 Page 3-9