Owner's manual

Table 4 Modbus Input Registers (continued)
Address Size Type Value Description Notes
33 2 Float 4-20mA Input 1 Measured analog input 1 in mA.
35 2 Float 4-20mA Input 2 Measured analog input 2 in mA.
37 2 Float 4-20mA Channel 1 Value output on 4-20mA Channel 1.
39 2 Float 4-20mA Channel 2 Value output on 4-20mA Channel 2.
41 2 Float Sensor Alpha 1
Relative scale factor between signal magnitudes
acq
uired from each sensor.
43 2 Float Sensor Alpha 2
Relative scale factor between signal magnitudes
acq
uired from each sensor.
45 2 Float Sensor Alpha 3
Relative scale factor between signal magnitudes
acq
uired from each sensor.
47 2 Float Sensor Alpha 4
Relative scale factor between signal magnitudes
acq
uired from each sensor.
49 2 Float Sensor Alpha 5
Relative scale factor between signal magnitudes
acq
uired from each sensor.
51 2 Float Sensor Alpha 6
Relative scale factor between signal magnitudes
acq
uired from each sensor.
53 2 Float Sensor Alpha 7
Relative scale factor between signal magnitudes
acq
uired from each sensor.
55 2 Float Sensor Alpha 8
Relative scale factor between signal magnitudes
acq
uired from each sensor.
57 2 Float
PreAmp Charge
Gain
Charge gain as read from the preamp.
59 2 Float PreAmp Gain 0 Preamp Gain 0 as read from the preamp.
61 2 Float PreAmp Gain 1 Preamp Gain 1 as read from the preamp.
63 2 Float PreAmp Gain 2 Preamp Gain 2 as read from the preamp.
65 2 Float PreAmp Gain 3 Preamp Gain 3 as read from the preamp.
67 2 Float Total Flow Fraction
Floating point fraction to be added to 'Total Flow Carry'
* 100 to cal
culate full resolution total flow.
Fractional part of totalizer. Add
this
number to Total Flow Carry *
100 to calculate full total.
20959-01 Rev 02 Page 3-1