➢ FACTORY DEFAULT
The factory settings assigned to each ray are shown in the table below:
Ray
No.
Application
Type
number
Application Type description
Vegetation
Filter
Interruption
Times
4
5
Birds Presence
1 = ENABLED
300mS
3
5
Birds Presence
1 = ENABLED
300mS
2
2
Corridors delimited on one side
only
0= DISABLED
100mS
1
0
Anti-crawling Basic
0= DISABLED
50mS
Non indicated Application default SET:
Application
Type
number
Application Type
Vegetation
Filter
Interruption
Times
4
Open areas
1 = ENABLED
50mS
3
Corridors delimited on both sides
1 = ENABLED
75mS
1
Anti-crawling Advanced
0 = DISABLED
75mS
4.1.2.2 Read/Write Barrier Number
Carrying the function switch SW1 to position 8, it is possible to read and/or set the barrier
number.
➢ Write barrier number:
• Select a number from 01 to 31 on the appropriate switches SW2 (tens) and SW3
(units).
• Press the button S3, to confirm its acquisition
Read the assigned barrier number:
• Turn the SW2 switch until the red LED (D9) is on
• Turn the switch SW3 until the red LED (D8) is on
The number from 01 to 31 represented on switches SW2 (tens) and SW3 (units), corresponds
to the barrier number currently assigned to the barrier.
Note: The barrier number must be the same as the one set on the corresponding TX ray and the
same for all the rays of the same barrier.