Installation Manual
© CIAS Elettronica S.r.l. Ed. 2.0
Installation Manual Page 45 of 49 MICRORAY
All the rays can be set with all 6 applications. The most suitable one with respect to
the ray position is recommended below:
Setting
Number
Application Type
Recommended
for the Ray
00
Anti-crawling Basic
1
01
Anti-crawling Advanced
1
02
Corridors delimited on one side only
2; 3; 4
03
Corridors delimited on both sides
2; 3; 4
04
Open areas
2; 3
05
Bird presence
3; 4
Select type of application:
• Select a number from 00 to 05 on the appropriate switches SW2 (tens) and SW3
• Press the button S3, to confirm its acquisition and use
Read type of application;
• Turn the SW2 switch until the red LED (D9) is on
• Turn the switch SW3 until the red LED (D8) is on
The number from 00 to 05 represented on switches SW2 (tens) and SW3 (units),
corresponds to the application number currently assigned to the ray.
➢ TYPES OF VEGETATION FILTER AND INTERRUPTION TIME OF RAYS
Now you can set the vegetation filter and interruption times of the rays by analysing the
environment in which MICRO-RAY is installed.
Carrying the function switch SW1 to position 5, it is possible to read and/or set the
vegetation filter and the interruption time of the rays.
Select the vegetation filter:
• Select a number from 0 to 1 on the switch SW2 (tens).
• Press the button S3, to confirm its acquisition and use
Read the vegetation filter:
• Turn the SW2 switch until the red LED (D9) is on
The possible selections are:
Position
Vegetation Filter
Functionality
0
DISABLED
Standard Functionality
1
ENABLED
Eliminates discontinuous
movements such as tree fronds.
Select interruption time:
• Select a number from 0 to 9 on the switch SW3 (units).
• Press the button S3, to confirm its acquisition and use
Read set interruption time;
• Turn the switch SW3 until the red LED (D8) is on
The number from 0 to 9 shown on switch SW3 (unit) corresponds to the times indicated in
the table below
Number
0
1
2
3
4
5
6
7
8
9
Time (ms)
10
20
35
50
75
100
300
500
750
1000