Installation Manual

© CIAS Elettronica S.r.l. Ed. 2.0
Installation Manual Page 37 of 49 MICRORAY
Terminal blocks, of the MICRO-RAY Interface circuit
The MICRO-RAY modules are all pre-wired in the factory and connected to the relative J1, J2,
J3, J4 terminal of the interface circuit (positioned approximately in the middle of the column), by
shielded F cable. Connect the shield to the SHLD pin of MS3 and MS4.
Figure 13 Topographical arrangement of the components in the circuit
TERMINAL BLOCK MS1 EXTERNAL CONNECTION TO MICRORAY
Term.
Block
Symbol
Function
1
13.8V
Positive Power Supply (+13.8 V )
2
GND
Negative for Power Supply and for Data (0 V )
3
LH
+ RS-485 High Data Line
4
LO
- RS-485 Low Data Line
5
PR
Power presence, Positive voltage input ( ) (referred to GND)
from external supply (**)
6
SHLD
Cable screen (*)
TERMINAL BLOCK MS2 IP-DOORWAY OR
SERVICE CONNECTION TO MICRO-RAY
Term.
Block
Symbol
Function
1
13,8V
Positive Power supply Input (+13.8 V )
2
GND
Negative Input for Power Supply and for Data (0 V )
3
LH
+ RS-485 High Data Line
4
LO
- RS-485 Low Data Line
TERMINAL BLOCK MS3
Term.
Block
Symbol
Function
1
SHLD
Cable screen (*)
2
PR
Power Presence (column internal connection)
TERMINAL BLOCK MS4
Term.
Block
Symbol
Function
1
SHLD
Cable screen (*)
2
SHLD
Cable screen (*)