Installation Manual

© CIAS Elettronica S.r.l. Ed. 2.0
Installation Manual Page 33 of 49 MICRORAY
Corners
The positioning in the corners is carried out side by side by placing the type A or type B columns
as shown in figure 10.
Figure 10
3 CONNECTIONS
Terminal blocks, Connectors and Functionality of the TX circuit
Figure 11 Topographical arrangement of the components in the circuit
TERMINAL BLOCK MS1
Term.
Block
Symbol
Function
1
TMP
Tamper Relay Contact (C) - Note 1
2
TMP
Tamper Relay Contact (NC) - Note 1
3
FLT
Fault Relay Contact (C)
4
FLT
Fault Relay Contact (NC)
5
STBY
Tamper Column Input (Norm. Closed to GND)
6
TEST
Power Presence Input (Norm. Closed to GND)
(Open when not used) - Note 1
7
GND
Reference potential for Tamper and Power Presence
8
SYNC
Not used
Note 1: Use only for ray 1, do not connect for the rays 2, 3, 4
1
MS1
TMP
TMP
B
B
B
B
A
A
A
A
S2
S1