Installation Manual
© CIAS Elettronica S.r.l. Ed. 2.0
Installation Manual Page 32 of 49 MICRORAY
Figure 8b
Note: Do not place the columns at a distance less than 50cm from the fence or 35cm from
the wall. (These distances are referred from the center of antenna).
Warning: With PARALLEL installation (fig. 8a), in some exceptional cases (normally
dependent on the type of fence or wall), the barrier placed at a distance ranging from 90cm
to 160cm from the wall/fence could be subject to phenomena that make a difficult alignment
of the rays positioned at middle height. In these cases, it is preferable to use the
DIAGONAL installation mode (fig. 8b) or dislocating the columns by 1m (fig. 8c).
Figure 8c
Warning: At the same way, if the barrier is installed PARALLELLY (fig. 8a) to a sidewalk,
or other structure, at least 15cm high, the low ray of the barrier could be subject to
phenomena that make a difficult alignment of the ray and could be present hypersensitivity
phenomena. In these cases, it is preferable to use the DIAGONAL installation mode (fig.
8b) or dislocating the columns by 1m (fig. 8c) or get away from the structure with the low
ray at least 50cm (fig. 8d).
Figure 8d
Installation between walls/fences
In the case of installation in corridors placed between two fences or walls or between fence and
wall you must follow the same indications shown above. See figures 9a and 9b.
Figure 9a
Figure 9b
A
B
1m
m
A
B
B
A
B
A
B
B
B
B
A
A
A
A
A
B
B
A
B
A
A
B
50cm