User's Manual
12
Recommended operating range: 0 °C to +45 °C
Temperature resolution: 0.1
°
C / 1
°
F (above 0
°
C)
1 °C / °F (below 0 °C)
Indoor relative humidity measurement range: 20% RH to 90% RH
Recommended operating range: 20% RH to 90% RH
Resolution: 1% RH
REMOTE SENSOR
Our temperature measuring range: -20 °C to +60 °C
Recommended operating range: -20 °C to +50 °C
Temperature resolution: 0.1 °C / 1°F (above 0 °C)
1
°
C /
°
F (below 0
°
C)
Remote relative humidity measuring range: 20% RH to 90% RH
Recommended operating range: 20% RH to 90% RH
Resolution: 1%RH
RF Transmission Frequency: 433MHz
No of remote unit: up to 3 units
RF Transmission Range: Maximum 30 meters
Temperature sensing cycle: around 60 ~ 64 seconds
Pressure measuring range: 800mb to 1050mb
Pressure sampling cycle: 15 minutes
Moon Phase Scanner Range: From 2000 to 2050
Radio Controlled Signal: DCF77
Power:
Main unit: 4.5 V, use 3 x AA 1.5V alkaline battery
Remote sensor: 3 V, use 2 x AAA 1.5V alkaline battery
Weight
Main unit: 298gm
Remote sensor: 53gm
Dimension
Main unit: 115 (W) x 220 (H) x 90(D) mm
Remote sensor: 65 (W) x 93 (H) x 27 (D) m