KP-700 Keypad Operation Manual Please read this manual carefully before use. Please keep it properly for further reference. Printed in Hong Kong PA: OI-KP700/EN-2013V1.
Table of Contents Usage Introduction Foreword 1 Arm 19 Parts List 2 Disarm 20 Appearance 3-4 Preparation before Use Power on 5 Connect Keypad to Control Panel 6 Connect RFID Tag to Keypad 6-7 Connect Electronic Door Lock 8 Installation 8 Stay Mode 21 Emergency Call 22 Mute Mode 22 Care and Maintenance Usage Notices 23 Maintenance 23 FAQ Settings Enter Setup State Delay Arm FAQ 24 9 10 Speed SOS Dial 11 Keyboard Clicks 12 Disarm by RFID Tag 13-14 Power Saving Mode 15
Foreword Parts List Thank you for purchasing this wireless keypad. It is recommended to install outside the entry door and users can achieve operations such as arm, disarm, stay mode after inputting passcode. Moreover, the keypad can connect with an electronic door lock to work as an access control system for homes and offices. When users are leaving rooms, just close the door, the electronic lock will be locked automatically.
Appearance Positive and negative terminals for battery AAA + + Battery slot LED Indicator Tamper Switch RFID reader Wired Cables Interface Arm Disarm Stay mode SOS key RFID wake-up key Rear cover + + RFID tag / card (125KHz) can be purchased separately. Max. 50 pcs are supported.
Preparation before Use Connect Keypad to Control Panel Make sure the control panel is in connecting state, input user code or admin code on keypad, and then press any key of Power on [Arm] [Disarm] [Stay Mode]. The connection succeeds after 1. Keypad uses 3pcs of AAA batteries. ① Loose the screw, open the case ② Put in batteries according to the positive and negative signs ③ Close the rear cover and screw on one beep. User can remotely control the panel via the keypad after connection.
2. Press [9], one beep is heard and the LED indicator is on. Keypad enters the learning state. Connect Electronic Door Lock To know connection steps, please refer to the instruction manual of electronic door lock. Installation Fix the keypad on the door frame or the wall before use. ① Loose the screw, open the case ② Fix the rear cover on the door frame or the wall by screws 3. Put RFID tag close to the RFID reader, the connection succeeds after one beep and the LED indicator goes out.
Settings The keypad should enter setup state before all settings. Delay Arm When the alarm system is armed, detectors will start working immediately. At that time, if you still stay at home, it will trigger an alarm. After setting delay arm, press [Arm] on the Enter Setup State keypad, the arm signal will be sent to the control panel after Input [admin code + #] to wake up keypad. the set time. This setting does not apply to Stay Mode.
Keyboard Clicks Speed SOS Dial User can choose to enable or disable speed SOS dial. If speed Keyboard clicks can be turned on or off. SOS dial is enabled, the control panel will alarm immediately If it is off, the successful setup tone will be closed too. when user holds the [SOS] key for 3 seconds. If it is disabled, user needs to input user code or admin code before holding the SOS key for 3 seconds. This function is to prevent false Turn off Keyboard Clicks operation or trick.
Disarm by RFID tag Disarming Silently by RFID Tag User can enable or disable the function of disarming by RFID tag, or disarming silently by RFID tag. The control panel and siren will hoot twice when disarming by RFID tag. If set disarming silently by RFID tag, the control panel and siren will keep silent to finish disarming without disturbing neighborhood.
Power Saving Mode When one beep is heard and the LED indicator keeps on for If the keypad is powered by batteries, power saving mode is 10 seconds, the setup is successful. recommended. In power saving mode, the keypad is in sleeping status when standby, user needs to press [*] to wake up the keypad and then put RFID tag close to the reader to Note! Default setting: 0, turn on power saving mode.
Change Admin Code Reset Using admin code can wake up keypad, send Arm, Disarm, After reset, the user code, admin code, and other settings will Stay Mode commands to the control panel, and also change restore to default except that the connected RFID tags can any settings of the keypad. still disarm and open electronic door lock. To avoid passcode reveal, please change admin code for first Enter setup state, input: 0 time.
Usage Disarm The keypad can be used as a remote control. User code or Users can disarm alarm system by using keypad or by using admin code should be input before the operation of Arm, RFID tags. Disarm, Stay Mode, and Mute Mode. Using Keypad to Disarm Arm Input user code or admin code, and press [Disarm] key, the LED indicator flashes once and the keypad beeps once and Input user code or admin code, and press [Arm] key, the sends Disarm command to the control panel.
Stay Mode Emergency Call Input user code or admin code, and press [Stay Mode] key, When the keypad is in Speed SOS Dial mode, user just holds the LED indicator flashes once and the keypad beeps once the [SOS] key for 3 seconds, the LED indicator flashes once, and sends Stay Mode command to the control panel. the keypad beeps once, and the control panel alarms immediately.
Care and Maintenance In order to avoid any harm to the users or others during usage and prolong the usage life, please abide by the following notices. FAQ Problem Usage Notices General instruction The keypad should be connected to control panel before use. No response from keypad The power supply of keypad will probably impact on the transmitting distance of wireless signal. The keypad can be powered by 3 pcs of AAA batteries, or wired by DC 12V. The keypad is compatible for any our alarm system.
Instructions of Wired Cables Interface (from Left to Right) +12V (RED WIRE): Positive of power GND (BLACK WIRE): Negative of power PUSH (YELLOW WIRE): Signal output for electronic lock GND (WHITE WIRE): Negative of power OPEN (GREEN WIRE): Signal input for exit switch 25 Technical Specifications Product Name: Keypad Model No.