M U LT I L I N G U A L EN FR ES PT O P E R AT I O N M A N U A L WK8000 Outdoor Keypad 2016 SMANOS HOLDING LTD. All Rights Reserved. Printed in China PA: WK8000-UM-ML-V1.0 Please read this manual carefully before using. Please keep it properly for further reference.
EN EN Table of Contents Foreword Package List Stay Mode Emergency Call Mute Mode Product Overview Notices and Maintenance Preparation before Use Usage Notices Maintenance Power on Connect Keypad to Control Panel Connect Keypad with RFID Tag Installation 5 6 6-7 8 Settings Enter Setup State Delay Arm Setting for SOS Function Keyboard Tone RFID Reader Setting Direct Arm/Disarm by RFID Tag Change User Code Change Admin Code Reset 9 10 11 12 13 - 14 15 - 16 17 18 19 Usage Arm Disarm 19 - 20 21 - 22
EN EN Foreword Package List Thank you for purchasing this wireless keypad. It is recommended to install outside the entry door and users can achieve operations such as arm, disarm, stay mode after inputting passcode. RFID tag/card x 1 Screw driver x 1 Keypad x 1 Screw kit x 1 1 AAA 1.
EN EN Product Overview LED Indicator Positive and negative terminals for batteryâ Battery compartment Tamper Switch RFIDâ reader RFID wake-up key Arm Stay mode SOS Disarm â Max. 50 pcs are supported. PR2600 3 â In case of low battery, the keypad sounds :"DiDi" for 6-7 times afte rpressing Arm,Disarm or Home arm.
EN EN Change batteries Slide the cover of the RFID reader, loose the screws of the four corners, open the lid of the battery compartment, change the batteries. Then cover all parts back. Connect Keypad to Control Panel Make sure the control panel is in connecting state, input user codeâ or admin codeê on keypad, and then press any key of . The connection succeeds after one beep. User can remotely control the panel via keypad after connection.
EN EN 2. Press [9], one beep is heard and the LED indicator is on. Keypad enters learning state. 3. Tap the RFID tag on the reader RFID reader, the connection succeeds after one beep and the LED indicator goes out. If two beeps are heard, it indicates the RFID tag has been connected before. Installation Before using the keypad to control the system, you have to install it to the doorframe or on the wall.
EN EN Settings Delay Arm The keypad should enter setup state before all settings. When the alarm system is armed, detectors will start working immediately. If you are at home during the time, an alarm will be triggered. After setting delay arm, press on the keypad, the arm signal will be sent to the control panel after the set time. Enter Setup State Input [admin code + #] to wake up keypad. If the control panel and the keypad both set a delay time, the actual delay time is the total of both times.
EN EN Setting for SOS Function Keyboard Tone Direct SOS Turn off Keyboard Tone Enter setup state, input: Enter setup state, input: When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. After the setting, pressing the SOS button for 3 seconds will trigger the alarm immediately. Input Code for SOS When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful.
EN EN RFID Reader Setting User can enable or disable the function of arming/disarming by RFID tag, or arming/disarming silently by RFID tag. Disable RFID Reader Enter setup state, input: RFID Tag Silent Mode By default, the control panel and siren beeps once when arming the system by RFID tag or beeps twice when disarming the system.
EN EN Direct Arm/Disarm by RFID Tag When direct Arm/Disarm by RFID tag is enabled, users can directly tap RFID tags to Arm/Disarm the system. However, the function consumes power greatly. It is suggested to disable the function, that is, set the keypad is in sleeping state. Users need to press the [*] key before tapping RFID tags. Disable Direct Arm/Disarm by RFID Tag Enable Direct Arm/Disarm by RFID Tag User can Arm/Disarm the system by RFID tag directly, which is convenient but consumes more power.
EN EN Change User Code Change Admin Code Using user code can wake up keypad, or send Arm, Disarm, Stay Mode commands to the control panel. Using admin code can wake up keypad, send Arm, Disarm, Stay Mode commands to the control panel, and also change keypad settings. Change User Code For your safety, it is suggested to change both user codes and admin codes after your purchase.
EN EN Reset After reset,both user code and admin code and other settings will be restored to default but the connected RFID tags are still valid. When the alarm panel receives the signal, the siren will beep once. The alarm system enters armed state. Enter setup state, input: When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Usage The keypad can be used as a remote control.
EN EN Disarm Using RFID Tag to Disarm Users can disarm alarm system by pressing keypad or by using RFID tags. If direct disarm by RFID tag is disabled, user needs to press [*] to wake up the keypad and then tap the RFID tag on reader to disarm the system. Using Keypad to Disarm Input user code or admin code, and press key, the LED indicator flashes once and the keypad beeps once and sends disarm signal to the control panel.
EN EN Emergency Call If the SOS function is set to direct SOS, user just holds the long blank key in the bottom for 3 seconds, the LED indicator flashes once, keypad beeps once, and the control panel alarms immediately. Notices and Maintenance In order to avoid any harm to the users or others during usage and prolong the usage life, please abide by the following notices. Usage Notices General instruction The keypad should be connected to control panel before use.
EN EN FAQ Problem No response from keypad Keypad cannot connect to control panel No response from the control panel by operating on keypad Cannot arm/ disarm by RFID Tags Keypad cannot be programmed Keypad cannot be armed, disarmed and in stay mode 25 Specifications Cause Solution Low battery Please change the battery Keypad is locked by inputting wrong passcode continually more than 6 times Keypad will be unlocked after non-operation for 20 seconds The positive and negative terminals are revers