User's Manual

Table Of Contents
2m
Ground
Installation
After making sure the detector works normally, do as follows:
Choose a suitable installation location
Fix the detector
Fix the bracket on the wall with screws and attach the detector to the
bracket.
Test the PIR motion detector
Press the test button at the back. It switches to the testing mode and
sustains for 3 minutes. Walk in the detection scope and observe the LED.
When body movement is detected, the LED blinks once.
Adjust the angle
Adjust the bracket angle to achieve the best detection effect.
Installation Notices
Mount the detector in a proper angle
The installation angle affects detection sensitivity. The sensitivity is optimal
when the walk direction is vertical to the infrared direction. Choose the best
location and angle according to the actual situation and detection scope
diagram.
Don't face glass windows or doors
Strong light interferes with detection sensitivity. In addition, complicated
situations, such as traffic flow, stream of people, also should be avoided.
Don't face or position close to heat sources
Heat and cold sources, such as heat extraction units, heaters, air conditioner,
microwave oven, refrigerator, which may cause false alarm, should be
avoided.
ON
Don't face swinging objects
Swinging objects may also trigger false alarm. Besides, if there are two
detectors covering the save scope, adjust the locations to prevent cross-
interference.
Specifications
Power Supply
DC 3V (AA 1.5V LR6 Battery x 2 pcs)
Static Current
≤ 90uA
Alarm Current
≤ 9.5mA
Detection Scope
8m/110°
Pet Immunity
≤ 25kgs
Transmitting Distance
≤ 80m (Open area/ no interference)
Radio Frequency
315MHz (±75KHz)
Housing Material
ABS plastic
Operation Condition
Temperature: -10°C~+55°C
Relative Humidity: ≤80% (non-condensing)
Detector Dimensions (L x W x H)
108 x 52 x 36.8 mm
Bracket Dimensions (L x W x H)
52 x 30 x 26.5 mm
Ver : PIR-910-EN-1405-V6.0
2014 Chuango. All rights reserved.
Mount the detector to a location close to the entry or exit
The detector aims at preventing intrusion. Detecting human movement at
the entry or exit is critical for security.
It is recommended to mount it at the height of 2m from the ground.
Note: If pet-immune function is applied, please do not adjust the angle up or
down, but keep it parallel with the wall.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
1.
(1)
(2)
2.