User's Manual
Fix the bracket on the wall with screws and attach the
detector to the bracket. Adjust installation height
or bracket to change the detection distance and angle.
It is recommended to mount it at the height of 2m from
the ground.
The detector is more sensitive to the cross movement
than to the vertical movement, so the performance of
detector is best when the detection direction is vertical
to the walking direction of people.
Ver: 900-EN-1212-2.0
2m
Installation & Notices
Avoid mounting the detector close to windows, air
conditioner, heater, refrigerator, oven, sunshine and places
where the temperature changes fast or the air stream flows
frequently. If two detectors are installed in the same
detection scope, please adjust the location to avoid
interference and false alarm.
Ground
Top view
Side view
In worki ng state, if the sensor is triggered
more than twice within 3 minutes, it will enter sleeping
mode to save power. After no movement within next 3
minutes, the sens or goes back to the worki ng mode.
Press the connect key on the
alarm panel , and then press the test butt on of the sensor
twice to send alarm signal . When one beep is heard, they
are connect ed. To check if they are connect ed succ essfully,
arm the system, and trigger the sensor agai n, if there is an
alarming, the connect ion is succ essful.
Working mode:
Connect to alarm panel :
Detection Scope
2m
4m
6m 8m0m
0m
2m
110°
Top view
Side view
Testing (Walk Test)
A. After installation, power on the detector. After one minute
self-testing, press the test button, walk in the scope (from
left to right or from right to left) and watch the LED
indicator to make sure the detector is working.
B. The LED indicator flashes once when body movement is
detected.
C. Adjust the detector angle accordingly to achieve the best
detection effect.
Mode Setting
Testing mode: After self-testing, press the test button,
the sensor enters testing mode, and detects once ever y
10 seconds. After 3 minutes, the LED flashes twice, and
the sensor enters the worki ng mode.
Test Button
Specifications
Power supply
Static current
Alarm current
Detection scope
Transmitting distance
Radio frequency
Housing material
Operation Condition
Detector dimensions (L x W x H)
Bracket dimensions (L x W x H)
DC 3V (AA 1.5V LR6 Battery x 2 pcs)
≤ 50uA
≤ 9.5mA
8m/110°
≤ 80m (in open area)
ABS plastic
Temperature: -10°C~55°C
Relative humidity: ≤80% (non-condensing)
108 x 52 x 36.8 mm
52 x 30 x 26.5 mm
315.8599MHz