Product Brochure
40
CHRONOMITE LABORATORIES, INC.
®
• 800-447-4962 • WWW.CHRONOMITE.COM
TECHNICAL: HOW TO SELECT YOUR WATER HEATER & AVERAGE GROUND TEMPERATURE
POWER REQUIRED KW
GALLONS PER MINUTE
30.0 87.8 131.8
29.0 84.9 127.4
28.0 82.0 123.0
27.0 79.1 118.6
26.0 76.1 114.2 152.3
25.0 73.2 109.8 146.4
24.0 70.3 105.4 140.6
23.0 67.3 101.0 134.7
22.0 64.4 96.6 128.8
21.0 61.5 92.2 123.0 153.7
20.0 58.6 87.8 117.1 146.4
19.0 55.6 83.5 111.3 139.1
18.0 52.7 79.1 105.4 131.8 158.1
17.0 49.8 74.7 99.6 124.5 149.3
16.0 46.9 70.3 93.7 117.1 140.6
15.0 43.9 65.9 87.8 109.8 131.8 153.7
14.0 41.0 61.5 82.0 102.5 123.0 143.5
13.0 38.1 57.1 76.1 95.2 114.2 133.2 152.3
12.0 35.1 52.7 70.3 87.8 105.4 123.0 140.6 158.1
11.0 32.3 48.3 64.4 80.5 96.6 112.7 128.8 144.9 161.1
10.0 29.3 43.9 58.6 73.2 87.8 102.5 117.1 131.8 146.4
9.0 26.4 39.5 52.7 65.9 79.1 92.2 105.4 118.6 131.8
8.0 23.4 35.1 46.9 58.6 70.3
82.0 93.7 105.4 117.1
7.0 20.5 30.7 41.0 51.2 61.5 71.7 82.0 92.7 102.5
6.0 17.6 26.4 35.1 43.9 52.7 61.5 70.3 79.1 87.8
5.0 14.6 22.0 29.3 36.6 43.9 51.2 58.6 65.9 73.2
4.0 11.7 17.6 23.4 29.3 35.1 41.0 46.9 52.7 58.6
3.0 8.8 13.2 17.6 22.0 26.4 30.7 35.1 39.5 43.9
2.0 5.9 8.8 11.7 14.6 17.6 20.5 23.4 26.4 29.3
1.0 2.9 4.4 5.9 7.3 8.8 10.2 11.7 13.2 14.6
0.5 1.5 2.2 2.9 3.7 4.4 5.1 5.9 6.6 7.3
20°F 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F
TEMPERATURE RISE °F
TECHNICAL:
FLOW VS. POWER REQUIRED