Product Brochure
12
CHRONOMITE LABORATORIES, INC. • 800-447-4962 • WWW.CHRONOMITE.COM
POINT-OF-USE ELECTRIC TANKLESS WATER HEATERS
INSTANTFLOW
®
CMICRO
MODEL CM SERIES
POINTOFUSE ELECTRIC TANKLESS WATER HEATER
WITH 0.20 GPM ACTIVATION FLOW RATE
INSTANT FLOW® MICRO
™
CM SERIES
LOW FLOW
˚F TEMPERATURE RISE @
MODEL ACTIVATION GPM VOLTS KW AMPS
90
˚C WIRE
0.35 GPM 0.5 GPM 1.0 GPM 1.5 GPM 2.0 GPM
CM-12L/120 0.20 120 1.44 12 14 AWG 28 20 --- --- ---
CM-15L/120 0.20 120 1.80 15 14 AWG 35 25 --- --- ---
CM-20L/120 0.20 120 2.40 20 12 AWG 47 33 --- --- ---
CM-30L/120 0.20 120 3.60 30 10 AWG 70 49 25 --- ---
CM-12L/208 0.20 208 2.50 12 14 AWG 49 34 --- --- ---
CM-15L/208 0.20 208 3.12 15 14 AWG 61 43 21 --- ---
CM-20L/208 0.20 208 4.16 20 12 AWG 81 57 28 --- ---
CM-30L/208 0.20 208 6.24 30 10 AWG 90+ 85 43 28 21
CM-40L/208 0.20 208 8.32 40 8 AWG 90+ 90+ 57 38 28
CM-12L/240 0.20 240 2.88 12 14 AWG 56 39 20 --- ---
CM-15L/240 0.20 240 3.60 15 14 AWG 70 49 25 --- ---
CM-20L/240 0.20 240 4.80 20 12 AWG 90+ 66 33 22 ---
CM-30L/240 0.20 240 7.20 30 10 AWG 90+ 90+ 49 33 25
CM-40L/240 0.20 240 9.60 40 8 AWG 90+ 90+ 66 44 33
CM-12L/277 0.20 277 3.32 12 14 AWG 65 45 23 --- ---
CM-15L/277 0.20 277 4.15 15 14 AWG 81 57 28 --- ---
CM-20L/277 0.20 277 5.54 20 12 AWG 90+ 76 38 25 ---
CM-30L/277 0.20 277 8.31 30 10 AWG 90+ 90+ 57 38 28
Notes: + = Above 90 Degrees
All heaters limited to factory set max temperature
Local plumbing and electrical codes must be followed for this installation of the water heater and accessories.
Factory preset temperatures available at 104°F , 110°F , 120°F / Optional - (ADJ) Field Adjustable temperature available 104F° -125F°.
1.4 9.6 KW
MODEL CM SERIES