Use and Care Manual

1 | P a g e
CHRONOMITE R-SERIES MIGHTY-MITE WATER HEATERS
INSTALLATION AND OPERATION INSTRUCTIONS (208-277V Models)
(Before installation, compare electrical requirements needed for the model of heater selected)
TABLE 1 Electrical Specifications
Model
Wattage
Total
Amps
1Φ Voltage
Circuit Breaker
Intermittent Duty Continuous Duty
R-48x/208
10,000
48
208
50 amp / 2 pole
60 amp / 2 pole
R-48x/240
11,500
48
220-240
50 amp / 2 pole
60 amp / 2 pole
R-58x/208
12,050
58
208
60 amp / 2 pole
80 amp / 2 pole
R-63x/208
13,100
63
208
70 amp / 2 pole
80 amp / 2 pole
R-48x/277
13,300
48
277
50 amp / 1 pole
60 amp / 1 pole
R-58x/240
13,900
58
240
60 amp / 2 pole
80 amp / 2 pole
R-68x/208
14,150
68
208
70 amp/ 2 pole
90 amp/ 2 pole
R-63x/240
15,100
63
220-240
70 amp / 2 pole
80 amp / 2 pole
R-75x/208
15,600
75
208
80 amp / 2 pole
100 amp / 2 pole
R-58x/277
16,050
58
277
60 amp / 1 pole
80 amp / 1 pole
R-68x/240
16,300
68
220-240
70 amp / 2 pole
90 amp / 2 pole
R-63x/277
17,450
63
277
70 amp / 1 pole
80 amp / 1 pole
R-75x/240
18,000
75
220-240
80 amp / 2 pole
100 amp / 2 pole
R-68x/277
18,850
68
277
70 amp / 1pole
90 amp / 1pole
R-75x/277
20,750
75
277
80 amp / 1 pole
100 amp / 1 pole
x = (L)-Low Activation
(S)-Standard Activation
(H)-High Activation
R-Series MIGHTY-MITE Specifications:
Dimensions: 9-3/4" (H) x 10-1/2" x 4-1/4"
Weight: 10 LBS
Materials:
Rugged steel housing and cover
Celcon plastic element assembly with nichrome coils
Minimum Operating Pressure: 25 PSI
Maximum Operating Pressure: 80 PSI
Maximum Pressure: 150 PSI
No pressure relief valve needed, unless required by local code.
Maximum Operating Temperature: 160°F
Listings: UL, UPC