Instructions / Assembly

CHRONOMITE TECHNICAL SUPPORT
TOLL FREE 800-477-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 5 of 8
START UP PROCEDURE:
1. Turn off electrical supply - open circuit breaker
2. Turn on water supply. Cycle hot side of faucet 10 times to assist in removing air bubbles.
3. Expel all air from lines and heater. Check for leaks at all fittings, joints and at water heater.
4. Turn on electrical power supply - close circuit breaker.
®
INSTANT-FLOW MICRO
INSTALLATION cont.
!
IMPORTANT
The manufacturer of this water heater will not be
liable for any damages due to the failure to follow
these installation and operation instructions.
!
NOTICE
Air in the heater may cause the elements to
burn out. If the water lines are drained, allowing
air into the heater, be sure to follow the following
start-up procedure:
Chronomite Laboratories is a Member of Morris Group International™
"GND" IS EARTH GROUND
L1
L2/N
ATTENTION:
UNIT MUST BE
HARD WIRED
CONDUIT CONNECTION PUNCHING
STRAIN RELIEF NOT SHOWN FOR CLARITY
SEE ELECTRICAL SPECIFICATIONS
FOR CORRECT WIRE SIZE.
NOTE:
HEATERS ARE SINGLE PHASE. ALL TESTS ARE
MEASURED AT THE OUTPUT OF THE HEATER.
FIGURE 2 WIRING CONNECTION
3100-002-001
II-928 3/16 REV 8