Instructions / Assembly

Model GPM LPM
FLOW CONTROL MODELS
FIGURE 2
FLOW CONTROL INSTALLATION
(See Parts List #8)
A212 2.0 7.6
OPERATION INSTRUCTIONS:
Ÿ Turn the hot water fixture to activate the flow switch. The flow switch activates at 0.65 gallons per minute (GPM) [2.5 LPM] and
deactivates at 0.50 gallons per minute (GPM) [1.9 LPM].
Ÿ If you increase the flow rate of the water the water temperature will become cooler. Cold water can always be mixed just as with a
conventional system if using a two handle faucet. Select the appropriate flow control.
Ÿ Once you decrease the hot water flow rate to 0.50 GPM [1.9 LPM] the unit will deactivate. It is not advisable to operate the heater
at 0.50 GPM [1.9 LPM] hot water flow rate.
NOTE:
1. Periodically inspect (4 times a year) the supply lines, connections and heater for any moisture, corrosion or other potential
preventable problems.
2. Prior to shutting off water valves for servicing, winterization, etc, always disconnect power from unit 1st.
3. Unit is intended to heat water only, and does not provide a means of cooling if inlet temperature exceeds set point temperature of
heater.
OPTIONS / FLOW CONTROLS
You may want to install the supplied flow control in your design. This high-quality control makes the water heating system operate
more effectively, as well as save water. the supplied 2.0 GPM [7.6 LPM] flow control assures that the flow rate will not exceed 2 GPM
[7.6 LPM]. however, less water can always be used. Consumer can mix the cold water as with a conventional system.
LOW FLOW RATE SYSTEM
For applications where 0.5 GPM [1.9 LPM] flow rate is desirable and / or where only 110 VAC is available, see our low flow rate
system outlined in installation #927
FLOW CONTROL SPECIFICATIONS
MATERIAL: Chrome plated, brass housing.
THREADING: MODEL 2.2 has DUAL threads 15/16” male
55/64” female
NOTE: Flow controls are adaptable to other thread configurations.
Please call factory If adapter or vandal proof model is needed.
CHRONOMITE TECHNICAL SUPPORT
TOLL FREE 800-447-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 6 of 8
!
IMPORTANT
Periodically inspect (4 times a year) the supply lines, connections and
heater for any moisture, corrosion or other potential preventable problems.
!