Instructions / Assembly

CHRONOMITE TECHNICAL SUPPORT
TOLL FREE 800-447-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 4 of 8
®
INSTANT-FLOW MICRO
INSTALLATION
!
CAUTION
A) Turn off the circuit breaker to avoid
dangerous electrical shocks.
B) Turn off the water supply.
C) Flush supply line of all foreign material such as
pipe dope, pipe chips, solder, sand, etc. before
making up supply connections after working on
water piping.
®
Chronomite Instant-Flow MICRO
See page 2 for selection
k Electrical junction supply box
(optional)
l Electrical supply conduit
m Electrical supply wire
n Dual outlet stop 3/8” Comp
outlet connections
o Fittings (supplied) 3/8” Comp
x 1/4” NPT
p Faucet supply inlet hoses
3/8” NPS
q Flow control A212 (supplied)
Dual threads 15/16 Male and
55/64 Female
HEATER INSTALLATION:
1. Remove cover off of water heater. Attach conduit to the conduit connection punching. Then feed wires. Do not attach
wiring.
2. Mount unit horizontally against the wall so the silver label reads correctly (See Figure 1). Use level to ensure unit is level
and mount with four screws through the flanges located on each corner using molly anchors or fasteners.
3. Connect plumbing. Use hose with 3/8” compression at cold water inlet and hot water outlet to 3/8” compression faucet
inlet connections (See Figure 1).
4. Run water through the unit to expel all air bubbles. Cycle hot side of faucet 10 times to assist in removing air bubbles.
Check for leaks at
all fitting joints. If no leaks proceed to electrical installation.
CAUTION: HEATING ELEMENTS MAY BURN OUT IF UNIT IS NOT MOUNTED HORIZONTALLY
ELECTRICAL INSTALLATION:
1. Connect power supply wires appropriately sized and protected by circuit breaker to the input terminals on the heater (hard
wired) as shown in the Figure 2 wiring diagram.
2. Refer to Table 1 above on Page 2 for the voltage and amperage of the supply power.
3. Ensure each wire L2/N, G, L1 are connected to the respective terminals.
4. Ensure water inlet valve to heater is open.
5. Turn on circuit breaker. Turn on water flow to exceed activation point listed in chart 2. The unit is almost ready for use.
Shut off circuit breaker.
6. Check for leaks at all fitting joints and also inside heater.
7. Install cover. Turn on circuit breaker. Unit is now ready for use.
8. Local plumbing and electrical codes must be followed in this installation of water heater and the accessories.
NOTES:
1. Failure to comply with code requirements voids the warranty.
2. Failure to install faucet flow control as shown on (Figure 3 page 6) may cause unsatisfactory operation of the heater.