Installation manual
Page | 35 PVT-MCT10A-EN
For the Homerun Layout and material selection, consult the field design layout provided by the
design engineer. Otherwise consult the Chromasun field design white paper.
7.3 Power/Data/Ventilation (PDV) Interconnects
The MCT’s may come shipped with desiccants attached to the ventilation ports. These are not
to be removed until the SFC and SFC wirings are completed. Following the completion of the
SFC and SFC wiring, then the PDV interconnects should be installed, and the desiccant should
be removed from the ventilation ports.
7.3.1 Parts List
Part
Part Name
Quantity
PDV Interconnects
Refer to Order
The power, data, and ventilation are all connected with the same type of ¾” liquid tight non-
metallic flex conduit. Within the PDV interconnect, shown in Figure 14, are data and power
jumpers each with a connector on both ends for connecting to the MCT. .
Figure 14: Power-Data-Desiccant Interconnect
NOTICE: Equipment Damage!
Do not unseal the PDV ports until ready to install. The interior of the MCT is designed
for indoor conditions. By opening the PDV port, the interior of the MCT is exposed to
the outdoor elements. If any foreign objects (i.e. moisture, mold) get inside they may
heavily damage the MCT. Also try your best to ensure that the installation of the PDV
interconnects are done during dry weather.