User`s manual

23
GBGB
GBGB
GB
Timer mode 6 [P22 = 10]Timer mode 6 [P22 = 10]
Timer mode 6 [P22 = 10]Timer mode 6 [P22 = 10]
Timer mode 6 [P22 = 10]
The instrument starts in "Power OFF" mode and it
remains in "Power OFF" mode until the contact is
closed.
When the contact has been opened the instrument
operates as follows:
- it starts the control using SP set point.
- it starts the time count down
- it energizes the Output 2
When the time count is equal to 0 the instrument
comes back to the "Power OFF" mode and the
output 2 will be reset.
1603E display management1603E display management
1603E display management1603E display management
1603E display management: when the
instrument starts the time count down, the upper
display shows the measured value while the lower
display shows time count down.
1601E display management1601E display management
1601E display management1601E display management
1601E display management: when the
instrument starts the time count down, the display
shows the time count down.
Pushing pushbutton, it is possible to display the
measured value.
NOTENOTE
NOTENOTE
NOTE: for both instruments, when the time is
finished the instrument comes back to the usual
display of the Power OFF mode.
SP
Time
Output 2
OFF
ON OFF
Contact
Closed Open Open
Closed
Stop Run Stop Run Stop Run
Output
Power
OFF
Output
Power
OFF
Timer mode 7 [P22 = 11]Timer mode 7 [P22 = 11]
Timer mode 7 [P22 = 11]Timer mode 7 [P22 = 11]
Timer mode 7 [P22 = 11]
The instrument starts in "Power OFF" mode and it
remains in "Power OFF" mode until a transfer from
open to close of the logic input is detected.
When the instrument detects this transfer, it starts
the control using SP set point and starts the time
count down.
When the time count is equal to 0 the instrument
comes back to the "Power OFF" mode .
1603E display management1603E display management
1603E display management1603E display management
1603E display management: when the
instrument starts the time count down, the upper
display shows the measured value while the lower
display shows time count down.
1601E display management1601E display management
1601E display management1601E display management
1601E display management: when the
instrument starts the time count down, the display
shows the time count down.
Pushing pushbutton, it is possible to display the
measured value.
NOTENOTE
NOTENOTE
NOTE: for both instruments, when the time is
finished the instrument comes back to the usual
display of the Power OFF mode.
SP
Time
Output
Power
OFF
Output
Power
OFF
ClosedOpen Open Open
Contact
1601-03-1-CX.pmd 13/01/2004, 10.4323