User's Manual

3
Programming
1. Z-Wave’s Group (Association Command Class Version 1)
The unit supports one association groups with five nodes. This has the effect that
when the unit is triggered, all devices associated with the unit will receive the
relevant reports.
1-1 Tamper Event Report (Alarm Report)
Press and hold the tamper switch more than 10 seconds then release, the unit
will send ALARM REPORT command to the nodes of Grouping 1 to inform
them there is a tamper event.
1-2 Control other Z-Wave Devices
When door/window is opened, the unit will send BASIC SET command which
contains a value that is adjustable, to the nodes of Grouping 1. For instance,
the brightness level of a lamp module can be fixed according to the set value.
However, the BASIC_SET command will be also sent to the nodes of
Grouping 1. For instance, a lamp module will be turned off after receiving the
BASIC_SET command.
Basic Set Command:
Event Present:
[Command Class Basic, Basic Set, Value = 255 (0xFF)]
Event Clear:
[Command Class Basic, Basic Set, Value = 0 (0x00)]
2. Z-Wave’s Configuration
2-1 Basic Set Level
When Basic Set Command is sent where contains a value, the receiver will
take it for consideration; for instance, if a lamp module is received the Basic
Set command of which value is decisive as to how bright of dim level of lamp
module shall be.
Example:
1-99: ON (Binary Switch Device)
Dim Level (Multilevel Switch Device)
Function Parameter Number Size Range Default
Basic Set level 1 1 1~99 99
Configuration Command
2-2 Configuring the OFF Delay
The Configuration parameter that can be used to adjust the amount of delay
before the OFF command is transmitted as Configuration Parameter #2.
This parameter can be configured with the value of 1 through 127, where 1
means 1 second delay and 127 means 127 seconds of delay.
Function Parameter Number Size Range Default
Basic Set level 2 1 0~127 1s
Configuration Command
3. Advanced Programming
The following information is for someone that has some experience setting up a
Z-Wave system or someone that has computer software running a Z-Wave
controller.
3-1 Battery Check Command
The users can also enquire the battery status of the unit by sending
BATTERY_GET command via Z-Wave Controller. Once the unit receives the
command, it will return BATTERY_REPORT command. The unit will send
Battery_Level = 255 (0xFF) command to the Z-Wave Controller to inform that
the unit is in low battery status.
BATTERY REPORT Command:
[Command Class Battery, Battery Report, Battery Level = 20%-100%]
ALARM_REPORT Command:
[Command Class Alarm, Alarm Report, Alarm Type = 0x01, Alarm Level =
0x11]