User's Manual
4
Accessory Mode
Clearing ID Code
1. Press the learning key āDā (as shown in page 1) for
more than 3 seconds and release, during which the
green LED should be at 2-second interval. This
implies HSE03 is now entering the ID code learning
mode. Green LED will flash repeatedly representing
the unit is waiting for receiving the ID code signal of
another accessory.
Within 30 seconds, press the learning key again for more
than 6 seconds and release, during which green LED
flash at 2-second interval repeatedly. it implies the ID code
learning procedure is completed.
2. Clearing outcome:
Indicator Status
LED none
LED
Green LED flash 4 times
(0.1 second on, 0.1 second off)
Note:
If ID code is cleared, green LED should flash at 2-second
interval repeatedly.
WARNING:
ID codes of all cooperative devices will be cleared after
executing ID code clearing function.
OPERATION
HSE03 should be tested with all the Controller to ensure it
can communicate with each of them successfully. To test
the communication between HSE03 and other Controller,
simply activate the cooperative unit after ID code learning
procedure is completed. If the communication is
successful, HSE03 should be triggered in a full alarm
condition/by giving an indication. If the communication is
failed, no response will be given.
MAINTENANCE & USAGE
* Do not immerse this unit in water or any other liquid.
* Do not cooperate the unit with more than 11 accessories.
* Due to building constructions, the operating range may
vary from 250 meters to a shorter distance, such as the
unit can only receive signals from pool alarm system
within a distance of 50 meters. Please test the unit to
find out a best operating range before mounting it. It is
also suggested not to mount the unit in the basement to
avoid poor transmissions.
(ST804)
Accessory
(SF802)
Accessory
(SM801)
Accessory
(HSC06) Gateway