User's Manual
2
1. Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode, within 1 second,
press On/Off button again until LED
is off or
2. Close and open manual switch input
of S1 or S2 between C three times
within 1.5 seconds at the first 3
minute when the first power is
applied will enter inclusion mode,
within 1 second, Close manual
switch input of S1 or S2 to C again
until LED is off.
Reset
3. Home ID and node ID will be
cleared and reset to factory default.
2-second on, 2-second off
1. Have Z-Wave Controller entered
association mode first.
Association
2. Pressing On/Off button three times
within 1.5 seconds will enter
association mode or
3. close and open manual switch input
of S1 or S2 between C three times
within 1.5 seconds at the first 3
minute when the first power is
applied will enter association mode
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the module is in, view from the LED for identification.
State Type LED Indication
Normal Under normal operation, toggle On/Off button between On and
Off. When pressing On, LED lights up, whereas Off, LED is off.
And when manual switch input from open (NO) to short (NC) or
from short (NC) to open (NO) will also trigger the toggle function.
No node ID Under normal operation, when the module has not been allocated
a node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing On/Off button, it will stop flashing
temporarily. However, after disconnecting and reconnecting the
wiring of the module, the LED will flash on and off alternately at
2-second intervals.
Overload When overload state occurs while the module is on, the module
will be converted to off right away of which LED flashes on and off
at 0.5-second intervals and on/off button will be lockout.
Overload state can be cleared by disconnecting and reconnecting
the wiring to the terminal block.
Choosing a Suitable Location
1. Do not locate the module facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the module is 0°C~40°C.
3. Do not locate the module where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of module will become a little bit hot of which
phenomenon is normal.
Installation
Note: Please note that it is a must to call for a licensed electrician for installation.
1. Install this module into a wall box of which wiring connection is shown hereunder:
2. After wiring connection is completed, execute inclusion and association process
between the module and remote controller.
3. There are different way to manually turn ON or OFF the module, first way is
using On/Off button, and the function behavior as below