User manual
Studio Force V 12 / T 12 / D 12 / D XT 12 User Manual 8 V1.3 March 2015
www.chroma
-
q.com
To set the DMX start address, press Enter, press Up/Down buttons to adjust DMX start address, press Enter for
2 seconds to save settings, the display goes back to Home.
Control Mode
The Studio Force V 12 / T 12 / D 12 / D XT 12 can be set to operate in 5 DMX controlled modes and 3
standalone modes. 2 grouping options are available cell-grouped (“Duo) and all-grouped (“All”). Refer to the list
below for details.
Press the Up/Down buttons to access the “Control Mode”, press Up/Down to select the mode and press Enter
for 2 seconds to save the settings.
Studio Force D 12, D XT 12 & T 12
Control Mode - Software Version 2.0
Mode Name Group Ch Description
1 Dim8x Duo 8 WWWW + WWWW
2 FxDim All 2 1 intensity Fx + All
3 Dim2x Duo 2 2 x W
4 Dim1x All 1 All
11 Look Sel 1 Look Select
12 Mastr StndAlon Standalone Master
13 Slave StndAlon Standalone Master
Manual Manual
Manual:
In this mode, the intensity level “Intensity” can be set and adjusted in standalone operation. From the main
menu, press Up/Down to access “Control Mode”, press Up/Down to select “Manual”, and then press Enter for 2
seconds to save the setting. Press Exit and the display will show “Manual Control” and the intensity level “00%
Intensity”. To adjust the levels press Enter once “00%” level will flash. Use the Up/Down buttons to adjust the
value and press Enter for 2 seconds to save the settings.
Studio Force V 12
Control Mode - Software Version 2.0
Mode Name Group Ch Description
1 WWWW Duo 8 WWWW + WWWW
2 sWWCW All 3 1 Intensity Fx + WW + CW
3 WW/CW All 2 WW + CW
4 CTI All 2 1 Colour Temperature + Intensity
11 Look Sel 1 Look Select
12 Mastr StndAlon Standalone Master
13 Slave StndAlon Standalone Master
Manual Manual
Manual:
In this mode, the intensity level “Int” and colour temperature “CT” can be set and adjusted in standalone
operation. From the main menu, press Up/Down to access “Control Mode”, press Up/Down to select “Manual”,
and then press Enter for 2 seconds to save the setting. Press Exit and the display will show “Manual Control” –
the level of colour temperature “CT 00%” and the intensity level “Int 00%”. To adjust the levels press Enter
once and the CT level will flash. Use the Up/Down buttons to adjust the value and press Enter again once and
the “Int” level will flash. Use the Up/Down buttons to adjust the value and press Enter for 2 seconds to save the
settings.