User manual
Color Block PSU-30 User Manual 9 V2.0 September 2012
www.chroma
-
q.com
Press Enter to toggle between Day, Hour (24) and Minutes, adjusting the setting with the scroll wheel as
desired. When the Day and Time is set correctly press Enter for 2 seconds to save settings.
Display Backlight (Displ. Backlight)
The LED display can be set to go off after 5 seconds of no activity. Press Enter, scroll wheel to On
(permanently) or Off (after 5 seconds) and press Enter for 2 seconds to save settings.
Reset to Default
Press Enter for 2 seconds to reset all menu items to factory defaults:
DMX address = 001, Control Mode = 1 (67 channels HSI+FX), DMX Lost = Hold, Looks = default, Display =
On, Frequency = 360, System = CB2
System
The PSU-30 can be set to operate for the Color Block DB4 system (CB1) and the Color Block 2 system (CB2).
Press Enter, scroll wheel to select CB1 or CB2, press Enter for 2 seconds to save settings.
Frequency
The PSU-30 has four frequency settings available - 360, 600, 1200, 2400. This allows for the LED scan rate
to be synchronised with the video camera and avoid a flickering effect. Press Enter, scroll wheel to select
frequency, press Enter for 2 seconds to save settings.
Sync Mode
In normal operation internally generated FX should stay synchronised between PSU-30’s for approx 30
minutes. If better synchronisation is required a timing signal can be run via a RJ45 patch (not crossover) cable
between PSU-30’s. In order for this to work correctly one PSU-30 must be designated as the Master and all
the others must be set to Slave.
Press Enter and use the scroll wheel to select Master or Slave. Press Enter for 2 seconds to save setting.
b. DMX personality mode 1-3
In mode 1 grouping is variable & in modes 2 -3 each cell is a group
PSU-30 (v2.1) Mode 1 (367ch)
7FX + 120 x HSI
Mode 2 (360ch)
120 x HSI
Mode 3 (360ch)
120 x RGB
(with *Magic Amber)
Channel 1 Grouping
0-100
Variable grouping range between
1-120 cells with FX running within the
group.
102-206
variable grouping range
between 1-120 cells with FX running
between the groups.
209-255
Variable grouping range for
every 2
nd
to every 120
th
cells in a group.
Hue for group 1 Red for group 1
Channel 2 Colour Speed
0-255
Variable speed of colour
scrolling. From static at 0 to maximum
at 255.
Saturation for group 1 Green for group 1
Channel 3 Colour Fan
0-255
Variable fan of colour between /
within groups. All units are the same
colour at 0.
Intensity for group 1 Blue for group 1
Channel 4 Colour Range Hue for group 2 Red for group 2