Remote operation mode (ro) 
Remote operation mode is used to select between the 3 control modes. The use of these different modes greatly enhances 
the versatility of the unit by giving the user remote control of the most of the functions. Press the brown or black buttons to 
switch between the modes (the default is Mode 1). Press red to save the new setting. 
Mode 1 =  Single channel DMX operation. The channel controls the colour selection. 
Mode 2 =  Dual channel DMX operation. The 1st channel controls the colour selection. 
The 2nd channel controls the fan speeds: 
0-24% = Fn 4 (fast), 25-39% = Fn 3, 50-74% = Fn2, 75-100% = Fn 1 (slow) 
Mode 3 =  Dual channel DMX operation. The 1st channel controls the colour selection. 
The 2nd channel controls the units other functions. 
These functions 
initialise two 
seconds after the 
channel level 
entered. 
Channel 2 level 
0-5% 
6-15% 
16-25%   
26-35%   
36-45%   
46-55%   
56-65% 
66-75%   
76-85%   
86-95%   
96-100% 
Feature 
= No feature 
= Fan off 
= Fan speed 1 (slowest) 
= Fan speed 2 
= Fan speed 3 
= Fan speed 4 (fastest) 
= Gel Saver off 
= Gel Saver on 
= Motor speed normal, see Speed mode (SP) 
= Motor speed fast, see Speed mode (SP) 
= Reset (reset to user defaults) 
Default Settings: 
User default settings 
Each time the red record button is pressed, the unit will save that change & these User defaults will take precedence on the 
next power cycle or remote reset. 
Factory default settings 
If the unit is reset, using the red button (held down) & the brown button pressed, the unit will reset to the Factory default 
settings.   
The Factory default settings put the unit in its safest operating mode.   
  Fan speed =    4 (fast) 
  Gel saver =    0 (off) 
  Gel speed =    1 (slow) 
  Display =    1 (on) 
  Remote operation =   1 (normal) 
  Display flip =    standard 