User manual

Color Force Compact User Manual 7 V1.8.1 December 2014
www.chroma
-
q.com
2.2
Cabling
The Color Force Compact system use XLR 4-pin connectors for power and control data input and through. The chassis are
ground bonded.
Power Supply Output Configuration: PSU15
Power Supply Output Configuration: PSU15Power Supply Output Configuration: PSU15
Power Supply Output Configuration: PSU15
WARNING!
PSU15
Output: Maximum of 5 fixtures per output – 48VDC, 6A per output.
Cable: The total cable length of the daisy chai
n per output must not exceed 60m/200ft.
Input: 100-120V~, 10A; 200-240V~, 5A; 50-60Hz
Fuse type & size: T12.5A 250V~
Power Supply Output Configuration: PSU
Power Supply Output Configuration: PSUPower Supply Output Configuration: PSU
Power Supply Output Configuration: PSU-
--
-300
300300
300
WARNING!
PSU-300
Output: 5 fixtures – 48VDC, 6A.
Cable:
The total cable length of the daisy chain must not exceed 60m/200ft.
Input: 100-120V~, 4A; 200-240V~, 2A; 50-60Hz
Fuse type & size: SLOW 5X20 4A 250V~
Output 2
Output 3
Maximum length of daisy chain per output = 60m/200ft.
Output 1
Maximum of 5 units per output
Maximum length of daisy chain per output = 60m/200ft.