Installation & Assembly

Installation Instructions for SPC Floors
SPC interlocking vinyl Flooring (Stone Plastic Composite) features interlocking planks for easy installation
and is installed as glue less floating floor. The interlocking planks lock together to provide a tight water
resistant seam, can be installed over most floor surfaces, and is suitable for both residential and light
commercial interior applications.
General information
1. Flooring should be transported and stored in a neatly stacked fashion on a smooth flat surface.
2. Acclimate the flooring and the rooms to be installed for 48 hours at a constant temperature
between 65° and 85°F (18.33° and 29.44°C) before, during, and maintained after installation.
3. SPC Planks should only be installed after other trades have finished and the jobsite has been
cleaned and cleared of debris that could potentially damage a finished plank installation.
4. Inspect flooring for damage, defects, or shading issues before installation; claims for visual defects
will not be accepted after cutting and/or installed.
5. Mix and install planks from several different cartons during installation to ensure a random
appearance.
6. Leave 1/4 inch (6.35mm) for expansion around the entire perimeter of the flooring.
7. Flooring should be protected from direct exposure to sunlight.
Subfloors:
SPC Floors can be installed over a variety of subfloor surfaces including concrete on all grade
levels, wood and many existing hard surface floors. The subfloors must be clean, smooth, flat,
solid (no movement), and dry. Do not install planks over floors that are sloped for drainage.
Any uneven areas greater than 3/16 inch (4.76mm) in a 10 foot (3.05m) radius should be leveled
with a Portland cement based patching compound.
SPC Plank is resistant to water damage but they do not prevent the transmission of moisture.
Care should be taken to keep moisture from collecting on either side of the flooring to prevent
the growth of unhealthy mold and mildew.