User manual
Section 7: Specifications
TVC-500 Operation Manual 7-5
020-100539-01 Rev. 1 (08-2010)
NOTE: This specifies frame rate for non-interlaced sources and field rate for interlaced sources. Signals will
be displayed at a lower rate (i.e., frames will be dropped).
7.6 Regulatory
7.6.1 Safety
• CAN/CSA C22.2 No. 60950-1-03 1st Edition
• UL 60950-1, 1st Edition
• IEC 60950-1:2001
Max. Capture Resolution per Channel 2048 x 1536 (analog), 1920 x 1200 (dig-
ital), 1080p (HD) - HDCP not supported
Input Connector Type DVI-I or HD15 VGA, HDMI, Compo-
nent (with adapter)
Power Consumption 15 Watts (Max.)
Power Requirements +3.3V @ 0.25A, +12V @ 2A
Horizontal frequency range 15 – 110kHz
Vertical frequency range1 25 – 200Hz
Scan format Progressive
Dot (pixel) clock rate Analog: 25 – 170MHz
Digital: 25 – 165MHz
Active pixels per scan line 640 min., 2048 max. (analog), 1920
max. (digital)
Active lines per field/non-interlaced frame 480 min., 1536 max. (analog), 1200
max. (digital)
Sync types Separate H and V
Composite (bi-level)
Sync-on-green (bi-level)
DVI Single Link
Polarity Positive or Negative (SOG Negative
only)
Input levels R,G,B – with sync:
R,G,B - without sync:
1.0Vp-p ±2dB (0.79Vp-p – 1.26Vp-p)
0.7Vp-p ±2dB (0.56Vp-p – 0.88Vp-p)
DC offset ± 2V
Nominal impedance 75 ohms