Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

4-10 CP2000 Setup Guide
020-100070-01 Rev. 1 (10/08)
Section 4: Maintenance
SET PROPER LAMP TYPE (POWER)
Skip this step if the new lamp is the same size as the old lamp. The Lamp Type will still be correct in
the Install menu.
If your new lamp is larger or smaller than the old lamp, record the new lamp type (2.0, 3.0, 4.5 or 6.0
kW) in the TPC Install menu before igniting the new lamp. This setting establishes the proper range of
power available for the installed lamp, ensuring the new lamp is neither under-powered nor over-
driven.
TURN LAMP ON
Press and hold the Lamp button from the TPC Main menu.
ADJUST LAMP POSITION
Using the TPC, adjust the lamp position within the projector. For more information, refer to 3.7
Working with the Lamp in the CP2000 User’s Manual. This ensures maximum performance, with the
lamp (bulb) well-centered with the reflector and distanced correctly from the rest of the illumination
system.
RECORD SERIAL NUMBER OF NEW LAMP
1. In the Advanced:Lamp menu, select New Lamp.
2. In the Lamp History submenu, enter the serial number in the text box.
3. Save to record the number and to reset the lamp timer. The timer will now begin to log time for the
new lamp.
4.4.2 FILTER REPLACEMENT PROCEDURE
Replace the air filter whenever the lamp module is replaced, or more frequently if operating the
projector in a dusty or dirty environment. Check monthly in all cases. The filter is located on the
operator side of the projection head, near the front (Figure 4-3 Air Filter Replacement).
1. Power down and disconnect from AC. Follow Steps 1-3 from the 4.4.1
Lamp Replacement
Procedure.
2. Loosen the two corner screws on the filter door and remove.
3. Remove the old filter and discard. Insert the new air filter, following the labeling for proper inside/
outside orientation. Slide all the way down into its slot.
WARNING
Do not attempt to ignite the lamp until its type (kW) is correctly set in the Install menu.
WARNING
Use only Christie filters. Never operate the projector without the filter installed.