Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

Section 4: Maintenance
CP2000 Setup Guide 4-9
020-100070-01 Rev. 1 (10/08)
3. Tighten set screws in both negative and positive lamp connectors (Figure 4-2 Secure bulb at
cathode (-) and anode (+) connectors).
IMPORTANT! Proper electrical contact prevents resistance in the lamp connectors.
If you accidentally touch the quartz body of the lamp with your bare hands, clean it as described in 4.3
Maintenance and Cleaning.
FIGURE 4-2 SECURE BULB AT CATHODE (-) AND ANODE (+) CONNECTORS
CHECK LEADS
Ensure the anode (+) lead between the lamp and igniter is well away from any projector metal, such as
the reflector or firewall.
CLOSE COOLING COMPARTMENT AND LAMP DOOR
The projector will not operate unless the louvered door is locked shut.
TURN BREAKERS ON
At the projector's breaker panel, turn all breakers ON.
WARNING
Leads too close to metal parts will cause arcing during starting pulse. This is a SAFETY
HAZARD and the lamp may not ignite.