Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

4-8 CP2000 Setup Guide
020-100070-01 Rev. 1 (10/08)
Section 4: Maintenance
3. Handling by the cathode end only, unscrew the lamp from the rear connector and carefully remove
from the projector. Immediately place the lamp inside the protective cover (saved from previous
installation) and seal it in a heavy carton on the floor where it cannot fall or be bumped.
4. With the lamp removed, visually inspect the reflector for dust. Clean if necessary, as described in
4.3
Maintenance and Cleaning.
REMOVE NEW LAMP FROM PROTECTIVE COVER
1. Remove tape, knurled nut and locking star washer (if present) securing the lamp within its cover.
2. Handling at the ends only, extract the lamp from the cover. Set aside the protective cover for re-use
in your next lamp disposal or for warranty return of an expired lamp.
INSTALL NEW LAMP
1. With protective clothing and shield on, insert the threaded cathode (-) end of the lamp into the
negative lamp connector nut located in the rear of the lamp compartment and screw in fully
(Figure 4-1 Install Bulb/Left). Hand-tighten only.
2. Rest the anode (+) end of the lamp on the lamp cradle (Figure 4-1 Install Bulb/Right) and slip the
positive lamp connector over the bulb end.
FIGURE 4-1 INSTALL BULB
WARNING
Handle box with extreme caution - the lamp is hazardous even when packaged. Dispose
of lamp box according to local area safety regulations.
CAUTION
Handle by the cathode/anode end shafts only, never the glass. Do not over-tighten.
Do not stress the glass.