Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

Section 4: Maintenance
CP2000 Setup Guide 4-7
020-100070-01 Rev. 1 (10/08)
4.4.1 LAMP REPLACEMENT PROCEDURE
NOTE: For this procedure you will need a compatible Christie Xenon CDXL or CXL lamp. Never
install a lamp intended for a different model or projector.
Read and follow all other general lamp precautions, as described in 4.1
Warnings and Guidelines.
TURN OFF MAIN AC
1. Allow the fans to run for at least 10 minutes in order for the lamp to completely cool.
2. At the breaker panel on the projector, set the 3-phase Main AC circuit breaker to OFF.
TURN OFF REMAINING CIRCUIT BREAKERS
After running the fans for at least 10 minutes, turn the remaining INTERNAL and PROJECTOR
circuit breakers, located on the breaker panel of the projector.
DISCONNECT PROJECTOR FROM AC SUPPLY.
OPEN LAMP DOOR
Will wearing protective clothing and shield unlock the lamp door and open it. If desired, release the
latch mechanism to remove the door entirely.
OPEN COOLING COMPARTMENT
Turn knob to open the inner lamp cooling compartment and reveal the cathode end (-) of the lamp.
REMOVE OLD LAMP AND INSPECT REFLECTOR
1. Loosen set screws from negative/cathode (rear, 7/64") and positive/anode (front, 3/16") lamp
connectors. These screws are shown in Figure 4-2 Secure bulb at cathode (-) and anode (+)
connectors. Apply minimal torque and do not stress the quartz tube.
2. Carefully slip the positive anode connector off the front of the lamp.
WARNING
Use the correct wattage lamp, supplied by Christie.
Lamp replacement must be done by qualified service technicians only.
Explosive Hazard - Wear authorized protective clothing whenever the lamp door is
opened. Never apply a twisting or bending force to the quartz lamp body.
WARNING
Never attempt to remove the lamp when it is hot. The lamp is under intense pressure
when hot and may explode, causing personal injury and/or property damage.
WARNING
Shock Hazard - Disconnect from all AC at all wall breakers.