Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

2-28 CP2000 Setup Guide
020-100070-01 Rev. 1 (10/08)
Section 2: Installation and Setup
ADJUST TOP/BOTTOM BORESIGHT
7. When left/right boresight is complete, focus the
image at the top edge of the screen (Figure 2-41).
If the bottom remains blurry while the top edge is
focused, refer back to Step 2, but place the paper
at the bottom of the screen to determine whether
the bottom of the image is focused in front of the
screen or behind the screen. If the bottom is well-
focused, proceed to Step 11.
8. Adjust the vertical boresight bolt (Figure 2-42)
using an Allen key to hold the bottom hex screw and another
to turn the adjustment bolt above it. Adjust as necessary to
direct or "aim" the lens toward the edge of the image, which
focused too close to the lens. When both top and bottom
appear equally blurry, re-focus at the top of the screen.
9. Adjust vertical offset to re-center the image on the screen.
10. Repeat Steps 8 and 9 until the top and bottom of screen are
both well-focused.
11. Although all sides of the image should now be in focus, the
center of the image will be slightly blurry at this point.
Refocus at center of image. The goal is good focus at center
and on all sides.
12. Adjust the "hold" screw to lock in place. Recheck boresight.
If present, swing the anamorphic lens in position in front of the
primary lens. It should magnify in the horizontal direction only,
stretching the image straight across the screen—this requires that its aperture (visible within the lens)
be vertically aligned with the screen. If the image appears skewed, loosen the locking ring on the
anamorphic lens and rotate the lens as necessary until the wide image is horizontal.
FOCUS PRIMARY LENS: With the anamorphic lens in place, re-focus the primary lens using focus knob.
The goal is good focus at center and on all sides.
FIGURE 2-43 FOCUS (ANAMORPHIC)
FOCUS ANAMORPHIC LENS: If horizontal focus in the image needs improvement, focus the
anamorphic lens too—rotate its barrel as needed.
FIGURE 2-41 ADJUST TOP
FIGURE 2-42 ADJUST TOP/BOTTOM
B
ORESIGHT










