Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

Section 2: Installation and Setup
CP2000 Setup Guide 2-15
020-100070-01 Rev. 1 (10/08)
342-456 VAC (Europe, etc.):
• If 3-phase and single-phase feeds (6-wire):
• Ensure ground wire is connected directly to the frame ground lug on the pedestal floor.
Attach no other wires here.
• Connect L and N @ 200-230 VAC (single-phase)
• Connect 1, 2, and 3 @ 342-456 VAC (3-phase)
• If 3-phase with neutral fed from 3-phase (5-wire):
• Ensure ground wire is connected directly to the frame ground lug on the pedestal floor.
Attach no other wires here.
• Connect 1, 2, 3, and N @ 342-456 VAC (3-phase)
• No L available. Connect jumper from 1 to L.
• If 3-phase only (4-wire):
This configuration is not possible. Use 5-wire or 6-wire only. Neutral is required.
SPECIAL ADJUSTMENTS FOR SOME AC SUPPLIES
AC levels can vary depending on region. Check the following when installing.
NOTES: 1) Requires voltmeter for up to 400 VAC. 2) Consult the Interconnect Drawing in pedestal.
Jumper from Igniter Terminal 2: As set from the factory, the igniter jumper located on terminal 2
connects to T2. This configuration is used when 207-265 VAC are present (as it is for most countries).
If you find your incoming AC is below 207 VAC, connect terminal 2 jumper to T1 instead.
FIGURE 2-21 CHECK VOLTAGE AND POSITION JUMPERS
WARNING
Ground (earth) connection is necessary for safety. Never compromise safety by
returning current through the ground.