Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

2-12 CP2000 Setup Guide
020-100070-01 Rev. 1 (10/08)
Section 2: Installation and Setup
2.1.4 INSTALL LENS(ES)
PRIMARY ZOOM LENS INSTALLATION
1. Orient your high-contrast lens with its notches at the top,
then fully insert the assembly straight into the lens mount
opening all the way back without turning. With the lens
fully back, it will seat properly within the lens mount and
the aperture will be oriented correctly.
NOTE: High Contrast lenses (only) have a flat on the rear
flange. Rotate the lens so that the flange clears two screws in the
mount. Also ensure the UP label is at the top to ensure proper
aperture orientation.
2. Lock the lens assembly in place with the lens clamp
DOWN.
NOTE: The lens seals the projector head, preventing
contaminants from entering the main electronics area. Never
attempt to operate the projector without a lens installed.
ANAMORPHIC LENS INSTALLATION
(OPTIONAL)
NOTE: Required only for 1.25x anamorphic lens, producing 2.39:1“scope” images.
If the anamorphic lens will be used, it is recommended that you now add the lens—and its motorized
mount—so that the additional weight will be present when correcting later for final leveling, boresight
and the like. Install only for those installations requiring full-size 2.39:1 “scope” images (mostly side-
masking screens).
1.
INSTALL THE ANAMORPHIC LENS MOUNT ON THE PROJECTOR: At the front of the projector,
install the motorized anamorphic lens mount hardware as described in the instructions provided
with the anamorphic lens mount kit.
2.
INSTALL THE 1:25x ANAMORPHIC LENS: Clamp the 1.25x anamorphic lens mount in place,
following the instructions provided with the anamorphic lens mount kit.
2.1.5 INSTALL FIRST LAMP
Install one of the following lamps in the projection head, depending on your model and site:
* For this projector, the 2.0 kW is available in CDXL (maximum performance) only
** Available as CDXL (maximum performance) or original CXL (less expensive).
Refer to full specifications in Section 8 of User MAnual
Table 2.2 Lap Models
CP2000i Lamps CP2000h/-S Lamps
2.0 kW* 2.0 kW**
3.0 kW** 3.0 kW **
4.5 kW**