Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

Section 2: Installation and Setup
CP2000 Setup Guide 2-7
020-100070-01 Rev. 1 (10/08)
8. Connect lamp leads (Figure 2-9 Route Lamp Leads Up and Connect Positive (+) White).
At the igniter:
• Ensure igniter door is open. From the ballast in the pedestal, route the main black and white lamp
leads through the nearby hole in the underside of the projection head (Figure 2-9 Route Lamp Leads
Up and Connect Positive (+) White).
• Route the NEGATIVE (-) BLACK lamp lead through the hole in the lamp cooling compartment wall
(Figure 2-9 Route Lamp Leads Up and Connect Positive (+) White).
• Connect the POSITIVE (+) WHITE lamp lead to the POSITIVE (+) igniter terminal. This terminal
also has a small PCB attached-stack this on top of the lamp lead (Figure 2-9 Route Lamp Leads Up
and Connect Positive (+) White).
• Close and lock the igniter door.
FIGURE 2-9 ROUTE LAMP LEADS UP AND CONNECT POSITIVE (+) WHITE
WARNING
Make sure the PCB directs to the back and remains at least 3/4" from the high-voltage
terminal (with braid connection).
Route all igniter wires AWAY from 9-pin and 15-pin connectors.
Twist both ballast cables twice-per-foot.