Setup guide
Table Of Contents
- 1 Introduction
- 2 Installation and Setup
- 2.1 Assembly and Connection of Components
- 2.2 Installing and Connecting Sources
- 2.3 Connecting for Communications
- 2.4 Adjust Tilt and Leveling
- 2.5 Initial Power Up
- 2.6 Maximizing Light Output
- 2.7 Basic Image Alignment
- 2.8 Offset and Boresight Alignment
- 2.9 Fold Mirror and Convergence Adjustments
- 2.10 Calibrating the System Using DCP Librarian Setup Software
- 2.11 Phase Balancing
- 3 Basic Operation
- 4 Maintenance
- 4.1 Warnings and Guidelines
- 4.2 Maintaining Proper Cooling
- 4.3 Maintenance and Cleaning
- 4.4 Replacing Lamp and Filter
- 4.4.1 Lamp Replacement Procedure
- Turn OFF Main AC
- Turn OFF Remaining Circuit Breakers
- Disconnect projector from AC supply.
- Open Lamp Door
- Open Cooling Compartment
- Remove Old Lamp and Inspect Reflector
- Remove New Lamp from Protective Cover
- Install New Lamp
- Check Leads
- Close cooling compartment and lamp door
- Turn breakers ON
- Set proper LAMP TYPE (power)
- Turn Lamp ON
- Adjust Lamp Position
- Record Serial Number of New Lamp
- 4.4.2 Filter Replacement Procedure
- 4.4.1 Lamp Replacement Procedure
- 4.5 Lens Replacement Procedure
- 5 Troubleshooting
- 5.1 Power
- 5.2 Lamp
- 5.3 TPC
- 5.4 Ethernet
- 5.5 Cinema Displays
- 5.6 Non-Cinema Displays
- 5.6.1 Projector is ON But There’s No Display
- 5.6.2 The Display is Jittery or Unstable
- 5.6.3 The Display is Faint
- 5.6.4 Upper Portion of Display Waving, Tearing or Jittering
- 5.6.5 Portions of Display Cut-off or Warp to the Opposite Edge
- 5.6.6 Display Appears Compressed (Vertically)
- 5.6.7 Data is Cropped from Edges
- 5.6.8 Display Quality Appears to Drift from Good to Bad and Vice Versa
- 5.6.9 Display Suddenly Freezes
- 5.6.10 Display Colors Not Accurate
- 5.6.11 Display Not Rectangular
- 5.6.12 Display is “Noisy”
- 5.6.13 Random Streaks at Bottom of Image

Section 2: Installation and Setup
CP2000 Setup Guide 2-5
020-100070-01 Rev. 1 (10/08)
1. Open both pedestal doors (Figure 2-5).
2. From the projection head, open the rear side door on the operator's side and open the lamp door
(Figure 2-5).
FIGURE 2-5 OPEN PROJECTOR FOR ACCESS
3. SET BALLAST AC INPUT SWITCH: Before connecting the ballast to AC, set the ballast’s AC input
switch to match the AC available at the site—toggle left for nominal 200 VAC supplies, and toggle
right for 400 VAC supplies. The factory default is 200 VAC.
4. Ballast ‘RS-232’ Cable: Connect the ballast's ‘RS-232’ cable 34-002075 to Panel B (9-pin),
routing through the small rectangular access hole in the front underside of the projection head
(Figure 2-6 Connect Ballast RS-232 and Interlocks to Projection Head). A second connector on
Panel B is pre-connected to Panel C. Any third connector is a non-functional spare.
5. Ballast Interlock Cable: Connect the ballast's interlock cable 34-002007 to Panel C (9-pin),
routing through the small rectangular access hole in the rear underside of the projection head
(Figure 2-6 Connect Ballast RS-232 and Interlocks to Projection Head). A second connector on
Panel C is pre-connected to Panel B and the remaining third connector is a non-functional spare.
FIGURE 2-6 CONNECT BALLAST RS-232 AND INTERLOCKS TO PROJECTION HEAD
NOTE: These cables also connect to the fire alarm interlock and dedicated outlet (both pre-connected
at manufacture).