Setup guide

Table Of Contents
CP2000 Setup Guide 2-1
020-100070-01 Rev. 1 (10/08)
2 Installation and Setup
This section outlines how to install, connect and optimize the projector.
2.1 ASSEMBLY AND CONNECTION OF COMPONENTS
NOTE: Illustrations apply to either CP model, unless otherwise stated. In some instances the
illustrations may not contain the rear-mount.
These instructions describe how to:
mount the projection head on to the pedestal
position the projector relative to the port window and screen
connect pedestal-to-head cabling and cooling hoses
customize projector for lamps
connect exhaust ducting and fill liquid cooling system
install lens and lamp
connect to power
2.1.1 BEFORE BEGINNING
You will require the following for installation:
Full understanding of all site requirements and characteristics
12” screwdrivers: Philips (magnetic) and flat
Assorted wrenches such as 7/8” and ¾”
Assorted Allen keys such as 3/16”, 7/64”, 5/32”, and M3
3-phase 4-wire, 5-wire, or 6-wire connection of AC supply to Terminal Block 1 in pedestal (certi-
fied electrician required).
Heat extractor (such as inline centrifugal blower Elicent model# AXC 315B) or roof extractor pro-
viding at least 600 CFM at 8” exhaust duct opening @ 600 watts or lower. NOTE: Mount at an
external location.
Lamp and protective clothing / safety gear
Laptop computer with DCP Librarian software with Ethernet or standard RS-232 cable
Vapor-free “dustoff type” compressed air can
Latex lab gloves
Lens cleaning tissue and solution (see 6.3, Maintenance & Cleaning)
CAUTION
All installation steps must be performed by qualified technicians. Do not modify circuits
or wiring.