6.4.1 Lamp Specification
Rated voltage 100 VAC – 240 VAC
Rated Current (dual lamp operation)
450W 1080p / SXGA+ / WUXGA 15 A @ 100 VAC
370W 1080p / SXGA+ / WUXGA / WXGA 12 A @ 100 VAC
200W 1080p / SXGA+ / WUXGA / WXGA 9 A @ 100 VAC
Line frequency 50/60 Hz
AC Input Coupler 15 A, 250 VAC
Type of connector IEC 320-C14 with wire cable clamp
Line Cord 14AWG type FT1 with plug, NEMA 5-15P, 15A
Inrush Current 60 A max
Maximum Power Consumption Dual Lamp
1080p / SXGA+ / WUXGA 1500W (dual lamp) / 750W (single lamp)
1080p / SXGA+ / WUXGA / WXGA 1320W (dual lamp) / 831W (single lamp)
1080p / SXGA+ / WUXGA / WXGA 1267W (dual lamp) / 805W (single lamp)
1080p / SXGA+ / WUXGA / WXGA 1135W (dual lamp) / 739W (single lamp)
1080p / SXGA+ / WUXGA / WXGA 871W (dual lamp) / 607W (single lamp)
1080p / SXGA+ / WUXGA / WXGA 739W (dual lamp) / 541W (single lamp)
Type Mercury Lamp (Hg)
Power
450W HD / SX+ / WU 360W min, 462W max (software adjustable)
350W HD / SX+ / WU / WX 300W min, 370W max (software adjustable)
200W HD / SX+ / WU / WX 150W min, 200W max (software adjustable)
DLV Models (HD / SX+) 150W only, (not software adjustable)
450W Lamp rated lamp life to 50% brightness 1250 hrs typical @ 450W
1500 hrs typical @ 360W
350W Lamp rated lamp life to 50% brightness 1300 hrs typical @ 370W
1500 hrs typical @ 350W
2000 hrs typical @ 300W
200W Lamp rated lamp life to 50% brightness 2000 hrs typical @ 200W
3000 hrs typical @ 150W
Warm-up time (to full output) 5 minutes max
Operating position ±20 degrees max tilt of lamp axis from horizontal