Setup guide
Section 2: Installation and Setup
M Series Setup Guide 2-9
020-100011-06 Rev. 1 (05-2013)
6. Adjust cross-hair pattern II, by adjusting the appropriate cap screw. Adjust until the cross-hair image is in
focus with minimal flare.
7. Adjust cross-hair pattern III, by adjusting the appropriate cap screw. Adjust until the cross-hair image is in
focus with minimal flare.
8. Repeat step 5, 6, and 7 as required until all 3 cross-hair patterns are in equal sharp focus. If the boresight is
acceptable, see step 11. If the boresight does not appear to be converging to an acceptable level of image
quality, or if the lens will not focus over the correct range of throw distances, then the boresight requires
coarse adjustment, see step 9.
9. The original factory boresight can be approximately recovered, by positioning the 3 setscrews flush with
the front face of the lens mount plate, and in contact with the inner lens mount plate, see Figure 2-3
Position Setscrew Flush. This may require adjusting both setscrews and cap screws.
10. If further action is required. Repeat 2.
11. Lock the setscrews, and re-check the boresight quality. Tighten the setscrew enough to ensure they will not
shift.
2.2.5 Powering Down
The projector can be powered down by using one of the following methods:
Remote Keypad/Built-In Keypad
• Press and hold POWER
-OR-
• Press P
OWER twice
-OR-
• Press P
OWER once, then immediately press the DOWN key.
NOTE: For Step 2 and 3, if the second key is not pressed immediately, a confirmation window will appear.
The second key press must be pressed within 1 second of the window appearing.
After powering down, the Status LEDs cycle and the LCD displays the message “Cooling Down”, until cool
down is complete.
Web User Interface (UI)
1. From the Main Tab, Select Power > OFF.
2. Select Yes.
FIGURE 2-3 POSITION SETSCREW FLUSH