User Guide
Section 4: Maintenance
4-8 RPMSP & CSP70-D100U User’s Manual
WARNING
DO NOT touch the glass surface of the lamp. Set it aside
for proper disposal once it has cooled down.
Figure 4.4.
WARNING
Never look or stick hands inside an open lamp
compartment while the other lamp is still ON. Power is
still present in the lamp module and the heat and U.V.
light from the remaining operational lamp could cause
physical injury.
Insert new lamp
a) Hold the new replacement lamp above the lamp compartment. Align the two
holes on the lamp module with the locating pins located on the edge of the
lamp compartment. See Figure 4.5.
b) Slide the lamp all the way down until it is fully seated into the compartment.
See Figure 4.6.
c) Tighten the two screws on the lamp module just until snug to hold it in place.
DO NOT over-tighten lamp screws as it could potentially damage the
lamp module.