Product Info

Table Of Contents
Chongqing Jinou Science &Technology Development Co., Ltd.
http://www.oemblue.com/ info@oemblue.com
19
6. Set / Inquire Sniff power-saving mode
Command
Response
Parameter
AT+SNIFF=<max>,
<min>,
<attemp>, <timeout>\r\n
\r\n OK\r\n
max: max time
min: min time
attemp: attemp time
timeout: timeout time
Default: 200, 32, 1,
8(Decimalism)
AT+SNIFF?\r\n
\r\n OK\r\n
\r\n SNIFF: <max>,
<min>,
<attemp>, <timeout>\r\n
Notes: This parameter will affect the power consumption of system.
7. Set / Inquire the parameters of inquiring scan and connecting
scan
Command
Response
Parameter
AT+SCANTIME=<pagein
t>, <pagewin>,
<inqint>, <inqwin>\r\n
\r\n OK\r\n
pageint: Connection interval
pagewin:
Duration of
connection
inqint: Inquire interval
inqwin: Inquire duration
Default: 2048, 18, 2048,
18(Decimal)
AT+SCANTIME?\r\n
\r\n OK\r\n
\r\n+SCANTIME:
<pageint>, <pagewin>,
<inqint>, <inqwin>\r\n
<pageint>: Connect scan interval(Range: 184096)
<pagewin>: Connect scan duration(Range: 174096)
<inqint>: Inquiry scan interval(Range: 184096)
<inqwin>: Inquiry scan duration(Range: 174096)
<pageint>must longer than<pagewin><inqint> must longer than <inqwin>
This parameter will affect the system power consumption
8. Set / Inquire whether authenticate
command
response
parameter
AT+AUTH=<enable>\r\n
\r\n OK\r\n
enable: 0 doesn’t need
authentication,
or needs
authentication
AT+AUTH?\r\n
\r\n OK\r\n
\r\n
AUTH: <enable>\r\n
Authentication: the security authentication is provided by the module. Only the
authenticated users can communicate with it. If it is a pair of modules, these processes are
done automatically. (Default password: 1234)