User`s guide

S
ECTION V:
DEVICE SETTINGS
Device Settings 913-623 @Rev A Section V, page
1
OVERVIEW OF
DEVICE
SETTINGS
The Device menus provide a view of current status and
access to dialogs for Diagnostics, Control and
Configuration.
Battery Status:
States are
Normal
,
Charging
or
Discharging
.
This value is returned as the
object:
UpsBatteryStatus
in
the UPS MIB - RFC1628.
Battery Charge Remaining:
Status
Current percentage of the
remaining total battery
charge.
This value is returned as the
object
upsBatteryChargeRemaining
in the UPS MIB - RFC1628.
Battery Voltage:
Voltage measured at the battery or charger output. This may be reported as "string" voltage
or "cell" voltage depending on the UPS model. This value is returned as the
upsBatteryVoltage
object in the UPS MIB - RFC1628
Internal Temperature:
The internal temperature reported by the UPS. This value is returned as the
upsBatteryTemperature
object in the UPS MIB - RFC1628.
Est. Battery Life:
Sometimes referred to as
Estimated Autonomy.
This is an estimate of the amount of
time the UPS batteries can sustain the current load. This value is continuously
recalculated based on the operating conditions of the UPS. When the UPS is on
battery, this value may decrease faster than expected due to battery age and other
variables that are difficult to model in the calculation algorhythm. (This value is
returned as the object;
upsBatteryEstimatedMinutesRemaining in the UPS MIB -
RFC1628)