Specifications
Cables for External Components
4-12 Stratus ftServer V 2302, V 4304, and V 6308 Systems: Site Planning Guide (R624)
cable connects the PC console to a U772 24-Port 10/100 Ethernet Switch to provide
web management capabilities of ftScalable Storage systems. See “Ethernet Cables”
on page 4-8 for details.
Cables for External Components
Table 4-4 describes component location considerations due to standard cable lengths.
Table 4-4. Cable Length and Component Location Considerations
Component 1 Component 2 Consideration Due to Shortest Cable
Cable
Length
PC console COM2 port on
CPU-I⁄O
backplane
Locate the PC console less than 25 ft. away
from the ftServer system due to the length of the
serial cable (B20253-25) provided with the
system.
25 ft.
(7.62m)
RSN console
server
COM1 port on
CPU-I⁄O
backplane
Locate the RSN console server less than 25 ft.
away from the system due to the length of the
Ethernet cable (B10106-25V) provided with the
system.
25 ft.
(7.62m)
RSN modem RSN console
server
Locate the RSN modem less than 10 ft. away
from the RSN console server due to the length
of the full modem cable (B10102-10V) provided
with the system.
10 ft.
(3.05m)
UPS units ftServer system Locate each UPS unit less than 8 ft. away from
the PDUs in the system cabinet due to the
length of each PDU AC input cord provided with
the system.
15 ft.
(4.57m)